Planning the RF300 system
4.4 Chemical resistance of the transponders
Substance
Calcium nitrate, w.
Chlorine
Chrome baths, tech.
Iron salts, w.
Acetic acid, w.
Ethyl alcohol, w., undenaturated
Formaldehyde, w.
Formalin
Glycerine
Isopropyl alcohol
Potassium hydroxide, w.
Lysol
Magnesium salts, w.
Methyl alcohol, w.
Lactic acid, w.
Sodium carbonate, w. (soda)
Sodium chloride, w.
Sodium hydroxide
Nickel salts, w.
Nitrobenzene
Phosphoric acid
Propane
Mercury
Nitric acid
Hydrochloric acid
Sulfur dioxide
Sulfuric acid
Hydrogen sulfide
Carbon tetrachloride
Toluene
92
Test conditions
Concentration [%]
Temperature [°C]
c. s.
c. s.
c. s.
50%
95%
95%
50%
30%
10%
10%
50%
c. s.
50%
50%
10%
10%
c. s.
c. s.
c. s.
10%
10%
10%
low
25%
10%
low
System Manual, 07/2016, C79000-G8976-C345-0x
Rating
20 ℃
○○○○
60 ℃
○○○
20 ℃
-
20 ℃
-
60 ℃
○○○○
20 ℃
-
20 ℃
○○○○
60 ℃
○○○
60 ℃
○○○○
20 ℃
○○○
20 ℃
○○○○
60 ℃
○○○
20 ℃
○○○
60 ℃
○○○○
20 ℃
○○○○
60 ℃
○○○
60 ℃
○○○○
20 ℃
○○
60 ℃
○○○○
60 ℃
○○○○
20 ℃
○○
20 ℃
○○○
60 ℃
○○
60 ℃
○○○○
60 ℃
○○○○
60 ℃
○○○○
60 ℃
○○○○
20 ℃
○○○
60 ℃
○○
20 ℃
○
60 ℃
○○○○
60 ℃
○○○○
20 ℃
○
20 ℃
○
60 ℃
○○○○
20 ℃
○○
20 ℃
○○○
60 ℃
○○○○
60 ℃
○○○○
20 ℃
○○○○
60 ℃
○○○
SIMATIC RF300