Siemens SIMATIC Ident System Manual page 86

Identification rfid systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Planning the RF300 system
4.3 Installation guidelines
Transponder
RF330T
RF340T
RF350T
RF360T
RF370T
RF380T
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
With ISO transponders (MDS D)
Table 4- 53
Transponder
MDS D100
86
Without metal
On metal; distance 0 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal; dis-
tance all-round 40 mm
Reduction of field data due to metal, range as %: Transponder and RF380R
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Reader RF380R (RF300 mode)
Without metal
On metal
100
90
70
65
100
90
70
65
60
60
100
85
70
65
55
50
100
95
75
70
60
55
100
95
90
85
65
60
100
95
95
90
65
60
Reader RF380R (ISO mode)
Without metal
On metal
100
95
65
60
55
50
System Manual, 07/2016, C79000-G8976-C345-0x
Flush-mounted
in metal
(20 mm all-
round)
80
60
80
60
55
80
60
45
85
65
50
85
80
60
85
80
55
Flush-mounted
in metal
(20 mm all-
round)
80
55
45
SIMATIC RF300