Reset Button - Resetting The Configuration To The Factory Settings - Siemens SCALANCE S612 Commissioning And Hardware Installation Manual

Scalance s series industrial ethernet security
Table of Contents

Advertisement

Insulation between the TP ports
Between the TP ports, an insulation voltage of 1.5 kV is adhered to (corresponds to
IEEE802.3, Section 33.4.1.1, Environment B).
See also
Technical specifications (Page 11)
4.3

Reset button - resetting the configuration to the factory settings

SCALANCE S switches have a reset button. The reset button is located on the rear of the
housing below the M32 plug immediately above the C-PLUG.
Image 4-1
Note
Make sure that only authorized personnel has access to the SCALANCE S device.
What does the reset button do?
Two functions can be triggered with the reset button:
● Restart
The device is restarted. The loaded configuration is retained.
● Reset to factory settings
The device is restarted and reset to the status set in the factory. A configuration loaded
on the SCALANCE S device or on an inserted C-PLUG is deleted.
SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
4.3 Reset button - resetting the configuration to the factory settings
Reset button and slot for the C-PLUG
Deployment planning
25

Advertisement

Table of Contents
loading

Table of Contents