7. Select your module and, if necessary, enter the IP address of the default router by
clicking in the "Default Router" column.
Optional: Configure any other properties of the module if required. You will find more
detailed information on this in the configuration manual "Industrial Ethernet Security -
Basics and Application" that can also be found on the product data medium.
8. Save the project with the following menu command: "Project" > "Save As...".
9. Select the module in the content area and select the menu command "Transfer" > "To
module...".
When you first load a configuration after installing the Security Configuration Tool, a
dialog appears in which you can select the required network adapter.
10.If you click on the "Start" button in the "Download configuration data to security module"
dialog, you transfer the configuration to the SCALANCE S module.
Result: The SCALANCE S module is now configured and can communicate at the IP
level. This mode is indicated by the Fault display being lit green.
SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
6.2 Step 2: Configuring and downloading
Commissioning
41