Intelligent Terminal Functions - Hitachi SJ700 series Manual

Powerful inverter with sensorless vector control
Hide thumbs Also See for SJ700 series:
Table of Contents

Advertisement

Code
Function Name
b108
Free-setting V/f frequency (5)
b109
Free-setting V/f voltage (5)
b110
Free-setting V/f frequency (6)
b111
Free-setting V/f voltage (6)
b112
Free-setting V/f frequency (7)
b113
Free-setting V/f voltage (7)
b120
Brake control enable (*3)
b121
Brake wait time for release (*3)
b122
Brake wait time for acceleration (*3)
b123
Brake wait time for stopping (*3)
b124
Brake wait time for conÞ rmation (*3)
b125
Brake release frequency setting (*3)
b126
Brake release current setting (*3)
b127
Braking frequency (*3)
b130
Overvoltage suppression enable
b131
Overvoltage suppression level
Acceleration and deceleration rate
b132
at overvoltage suppression
b133
Overvoltage suppression propotional gain
b134
Overvoltage suppression Integral time
b141
Output loss detection enable (SJ700D only)
b142
Output loss detection sensibility (SJ700D only)
b164
Automatic return to initial display (SJ700D only)
b166
Data Read/Write select (SJ700D only)
b180
Initialization trigger (SJ700D only)
(*1) 4000HF: 0.00 to 120.0 (Hz)
● C GROUP: INTELLIGENT TERMINAL FUNCTIONS
Code
Function Name
C001
Terminal [1] function (*1)
C002
Terminal [2] function
C003
Terminal [3] function (*1)
C004
Terminal [4] function
C005
Terminal [5] function
C006
Terminal [6] function
C007
Terminal [7] function
C008
Terminal [8] function
C011
Terminal (1) active state
C012
Terminal (2) active state
C013
Terminal (3) active state
C014
Terminal (4) active state
C015
Terminal (5) active state
C016
Terminal (6) active state
C017
Terminal (7) active state
C018
Terminal (8) active state
C019
Terminal FW active state
(*1) When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003",
respectively. (You cannot arbitrarily write "64" to "C001".) If the SW1 signal is turned o and then turned on, "no" (no assignment) is set in parameter "C003".
(*2) 1850HF,2200HF,3150HF and 4000HF:The function is not provided.
19
0. to "free-setting V/f frequency (6)" (Hz)
0.0 to 800.0 (V)
0. to "free-setting V/f frequency (7)" (Hz)
0.0 to 800.0 (V)
0.0 to 400.0 (Hz) (*4)
0.0 to 800.0 (V)
00 (disabling), 01 (enabling)
0.00 to 5.00 (s)
0.00 to 5.00 (s)
0.00 to 5.00 (s)
0.00 to 5.00 (s)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
SJ700/SJ700D: 0.0 to 2.00 x "rated current" (A)
< 75kW and over:0.0 to 1.80 x "rated current" (A)>
SJ700B: 0.0 to 1.50 x "rated current" (A)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
00 (disabling the restraint), 01 (decelerating and stagnating),
02 (enabling acceleration with deceleration),
03 (enabling acceleration) (SJ700D only)
330 to 390 (V) (200 V class model), 660 to 780 (V) (400 V class model)
0.10 to 30.00 (s)
0.00 to 2.55
0.000 to 9.999 / 10.00 to 63.53 (s)
00 (disabling), 01 (enabling)
1.to 100.(%)
00 (disabling), 01 (enabling)
00 (Read/Write OK), 01 (Protected)
00 (Initialization disable), 01 (Perform initialization)
(*2) 4000HF: 0.00 to 99.99, 100.0 to 120.0 (Hz)
01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting), 03 (CF2: Multispeed 2
setting), 04 (CF3: Multispeed 3 setting), 05 (CF4: Multispeed 4 setting), 06 (JG:
Jogging), 07 (DB: external DC braking), 08 (SET: Set 2nd motor data), 09 (2CH:
2-stage acceleration/deceleration), 11 (FRS: free-run stop), 12 (EXT: external
trip), 13 (USP: unattended start protection), 14: (CS: commercial power source
enable), 15 (SFT: software lock), 16 (AT: analog input voltage/current select), 17
(SET3: 3rd motor control), 18 (RS: reset), 20 (STA: starting by 3-wire input), 21
(STP: stopping by 3-wire input), 22 (F/R: forward/reverse switching by 3-wire
input), 23 (PID: PID disable), 24 (PIDC: PID reset), 26 (CAS: control gain setting),
27 (UP: remote control UP function), 28 (DWN: remote control DOWN function),
29 (DWN: remote control data clearing), 31 (OPE: forcible operation), 32 (SF1:
multispeed bit 1), 33 (SF2: multispeed bit 2), 34 (SF3: multispeed bit 3), 35 (SF4:
multispeed bit 4), 36 (SF5: multispeed bit 5), 37 (SF6: multispeed bit 6), 38 (SF7:
multispeed bit 7), 39 (OLR: overload restriction selection), 40 (TL: torque limit
enable), 41 (TRQ1: torque limit selection bit 1), 42 (TRQ2: torque limit selection
bit 2), 43 (PPI: P/PI mode selection), 44 (BOK: braking conÞ rmation), 45 (ORT:
orientation), 46 (LAC: LAD cancellation), 47 (PCLR: clearance of position
deviation), 48 (STAT: pulse train position command input enable), 50 (ADD:
trigger for frequency addition [A145]), 51 (F-TM: forcible-terminal operation),
52 (ATR: permission of torque command input), 53 (KHC: cumulative power
clearance), 54 (SON: servo-on), 55 (FOC: pre-excitation), 56 (MI1: general-
purpose input 1), 57 (MI2: general-purpose input 2), 58 (MI3: general-purpose
input 3), 59 (MI4: general-purpose input 4), 60 (MI5: general-purpose input 5),
61 (MI6: general-purpose input 6), 62 (MI7: general-purpose input 7), 63 (MI8:
general-purpose input 8), 64 (EMR: Emergency stop) (*1), 65 (AHD: analog
command holding), 66 (CP1: multistage position settings selection 1 ), 67 (CP2:
multistage position settings selection 2), 68 (CP3: multistage position settings
selection 3), 69 (ORL: Zero-return limit function), 70 (ORG: Zero-return trigger
function), 71 (FOT: forward drive stop), 72 (ROT: reverse drive stop), 73 (SPD:
speed / position switching), 74 (PCNT: pulse counter), 75 (PCC: pulse counter
clear), 82 (PRG: EzSQ program) (SJ700D only), no (NO: no assignment)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
Monitored data or setting
(*3) SJ700D (VT): Not available (no display)
Monitored data or setting
[⃝ = Allowed
Default Setting
SJ700/SJ700D(CTmode)
SJ700B
(allowed or not)
-FE
-FU
-F
-F
-FU
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Rated current x 1.00
0.00
0.00
0.00
0.00
0.00
00
00
00
00
00
380/760 380/760 380/760 380/760 380/760
1.00
1.00
1.00
1.00
1.00
0.50
0.50
0.50
0.50
0.50
0.060 0.060 0.060 0.060 0.060
×
×
00
00
00
×
×
10.
10.
10.
×
×
00
00
00
×
×
00
00
00
×
×
00
00
00
[⃝ = Allowed
Default Setting
SJ700/SJ700D(CTmode)
SJ700B
(allowed or not)
-FE
-FU
-F
-F
-FU
18
18
18
18
18
(RS)
(RS)
(RS)
(RS)
(RS)
16
16
16
16
16
(AT)
(AT)
(AT)
(AT)
(AT)
06
06
06
06
03
(JG)
(JG)
(JG)
(JG)
(CF2)
11
11
11
11
02
(FRS)
(FRS)
(FRS)
(FRS)
(CF1)
09
09
09
09
01
(2CH)
(2CH)
(2CH)
(2CH)
(RV)
03
13
03
03
06
(CF2)
(USP)
(CF2)
(CF2)
(JG)
02
02
02
02
11
(CF1)
(CF1)
(CF1)
(CF1)
(FRS)
01
01
01
01
13
(RV)
(RV)
(RV)
(RV)
(USP)
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
01
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
×
= Not permitted]
Setting
Change
during
during
operation
operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
= Not permitted]
Setting
Change
during
during
operation
operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×