Ease Of Maintenance; Easy Operation; Network Compatibility - Hitachi SJ700 series Manual

Powerful inverter with sensorless vector control
Hide thumbs Also See for SJ700 series:
Table of Contents

Advertisement

Ease of maintenance

Easy-removable construction
for maintenance
Field replacement of cooling fan (s) and DC bus capacitors
can be accomplished in a fraction of the time.
Using Logic terminal move to SJ700D/SJ700 without wiring
change.
Read SJ300 Parameter by WOP remote operator and write
them in to SJ700D/SJ700
Easy-removable
Cooling Fan
SJ300series
Removable Control circuit terminals
(Move to SJ700D/SJ700 without rewiring)
*1 Control circuit terminals comparison table
Series
SJ700D/SJ700
SJ700B
(Intelligent 8terminals,FW)
SJ300
L300P
(Intelligent 5terminals,FW)
Long lifetime components &
Lifetime warning function
Long lifetime components
Design lifetime 10 Years or more for DC bus capacitors & Cooling
Fan.Cooling Fan ON/OFF control function for longer fan life.
*Condition for lifetime calculation -
Ambient temperature: 40 deg C (SJ700B: 30 deg C)
Ambient condition: No corrosive gas, oil mist nor dust
10 years is a design lifetime base on calculation, and not guaranteed
Lifetime warning function
Lifetime warning function helps to perform preventive
maintenance before a failure occurrence.
DC bus capacitor, cooling fan, heat sink temperature and
motor temperature can be monitored in order to replace
components prior to failure.
5
Easy-removable
DC bus Capacitors
(SJ700D/SJ700: above 15kW
SJ700B: above 18.5kW)
SJ700series
Parameter
read write
Input terminals
Output terminals
9 terminals
5 terminals
(Open collector outputs)
2 terminals
6 terminals
(Relay outputs)

Easy operation

User selection of displayed
parameters
Data comparison display mode
Displays only parameters changed from factory default
User-define parameter display mode
Displays only user defined parameters
(up to 12 parameters, U001 to U012)
Basic parameter display mode
Displays only pre-defined basic parameters which are used
commonly
Basic
mode
Chose Basic
Parameter
Other functions
Direct digit edit mode for quicker selection of parameter.
Returning to output frequency monitor display (d001) by
holding the FUNC key for 3 seconds regardless of the
current content.

Network compatibility

The Modbus-RTU communication is embedded as standard
along with a dedicated terminal.
Other fieldbus communications such DeviceNet and
PROFIBUS-DP are supported with optional fieldbus modules.
-DeviceNet is a trade mark of Open DeviceNet Vender Association, Inc.
-PROFIBUS-DP is a registered trade mark of PROFIBUS Nutzer
Organization
Simple & Low cost wiring, ease of installation
and replacement using feildbus commuincation
Indication only
Basic Parameter