Signal names
The signal names in the following tables mean:
P5
GND
P5EXT
M5EXT
Signal types
The signal types in the following tables mean:
B
I
O
V
OC
X102
PROFIBUS DP interface
Connector name:
Connector type:
Maximum cable length:
Special features:
Table 4-3
*) 24 V only present if 24 V is fed to X121 (cable distributor).
Signal names
RS, XRS
ORTSAS
IRTSPG
X111
P-bus/K-bus
Connection of S7-300 I/O and single I/O module
Connector name:
Connector type:
Maximum cable length:
Special features:
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
Logic power supply 5 V
Logic reference potential ground
Logic power supply 5 V isolated
Logic reference potential for P5EXT
Bidirectional
Input
Output
Voltage
Open Collector
X102 pin assignments
Pin
Name
1
Not assigned
2
M24EXT *)
3
RS_L2DP
4
ORTSAS_L2DP
5
M5EXT
4 Description of the SINUMERIK 810D
X102
9-pole D-Sub socket connector
200 m
isolation (safe isolation)
12 MBaud
X102
Type
Pin
Name
6
P5EXT
VO
7
P24EXT *)
B
8
XRS_L2DP
O
9
IRTSPG_L2DP
VO
RS485 data
Request to Send programmable controller
Request to Send programming device
X111
25-pole D-Sub socket connector
10 m
non-isolated (no safe isolation)
4.2 Interfaces
Type
VO
VO
B
I
4-53