5. OUTDOOR FAN CONTROL

1. Outdoor Fan Motor
The Table 5 shows the fan speed of the outdoor unit.
( Table 8 : Fan speed of the outdoor unit )
AOU36RLXFZH
AOU45RLXFZ

6. COMPRESSOR CONTROL

7. COMPRESSOR CONTROL
1. OPERATION FREQUENCY RANGE
1. OPERATION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the Table 9 .
( Table 9 : Compressor operation frequency range )
AOU36RLXFZH
AOU45RLXFZ
2.
2. OPERATION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the Fig. 12 .
( Fig. 12 : Compressor control at Start-up )
H rps
G rps
E,F rps
C,D rps
B rps
A rps
G
H
[ Frequency ]
A rps
AOU36RLXFZH
AOU45RLXFZ
[ Time ]
G ~ H
AOU36RLXFZH
60sec
AOU45RLXFZ
Cooling
890/ 830/ 710/ 640/ 580/ 520/
460/ 390/ 340/ 290 rpm
Cooling
Min
Max
20
80
20
100
I
J
K
L
B rps
C rps
30
36
47
H ~ I
I ~ J
60sec
480sec
01-15
Heating
910/ 830/ 710/ 640/ 580/ 520/
460/ 390/ 340/ 290 rpm
Heating
Min
Max
20
120
20
110
M
N
D rps
E rps
F rps
47
60
60
J ~ K
K ~ L
L ~ M
120sec
300sec
180sec
O
G rps
H rps
80
100
M ~ N
N ~ O
120sec
120sec