SERVICE PARTS INFORMATION 8
Active filter module
Test 1 : Check Open or Short-circuit and Diode (D1)
Remove connector, check the open or short-circuit and the diode in the module
Check the open or short-circuit
Table.1 Each type standard value
Terminal
SACT32010 [ HITACHI ]
LACT33020 [ HITACHI ]
multimeter
multimeter
PM-601 [ FGEL ]
(+)
(-)
+
(+IN)*
-
( -IN)*
-
( -IN)*
*
N1
(N)
+
(+IN)*
P
1.01M
L1
L2
(Ref. value 1)
P
N1
(N)*
L1 , L2
Control Box
1.65M
L2
N1
(N)*
(Ref. value 1)
* ( ) is FGEL terminal name.
Table.2 Standard value is changed by the tool specification
(Type A and B are the same value)
Terminal
multimeter
multimeter
(+)
(-)
L2
P
P
L2
By kind of multimeter , the value may change significantly.
Ref. value 1
Specifications for Multimeter
Manufacturer : FLUKE
Model name : FLUKE11
Power source : DC9V.
If it is abnormal,replace ACTIVE FILTER MODULE
Test 2 : Check the Output DC voltage (between P and N)
Check the Output DC voltage (between P and N) of compressor stopping and operating.
>> If the output voltage of compressor operating is less than the output voltage of compressor stopping,
Active Filter Module is detective. >> Replace Active Filter Module
Resistance value
Type A
PM-604 [ FGEL ]
PM-703 [ FGEL ]
PM-601 [ FGEL ]
LOT No. 1302931396 -
LOT No. - 1302931395
+ -
360k
20%
0
+ -
720k
20%
/
0.76M
(Ref. value 2)
+ -
360k
20%
/
1.14M
(Ref. value 2)
Resistance value
1.32M
/
0.66M
(Ref. value 1)
(Ref. value 2)
1.01M
/
0.76M
(Ref. value 1)
(Ref. value 2)
Ref. value 2
Specifications for Multimeter
Manufacturer : SANWA
Model name : PM3
Power source : DC3V.
02-57
LOT No. of PM-601 [ FGEL ] type
Label position
Type B
+ -
360k
20%
0
Label
+ -
900k
20%
1.01M
/
0.76M
(Ref. value 1)
(Ref. value 2)
+ -
540k
20%
Model name
1.65M
/
1.14M
(Ref. value 1)
(Ref. value 2)
+
(+IN)*
-
( -IN)*
Lot No.(10 figures)
L1
L2
P
N1
(N)*