Fujitsu ASU18RLF Service Instructions Manual page 98

Split type room air conditioner compact wall mounted / wall mounted / floor compact cassette / slim duct inverter multi
Hide thumbs Also See for ASU18RLF:
Table of Contents

Advertisement

SERVICE PARTS INFORMATION 9
IPM
(Mounted on Transistor PCB)
Test 1 : Check the Transistor of PCB ( for Resistance )
Disconnect the connection wires between the Transistor
PCB - Capacitor PCB and Transistor PCB - Inverter
Compressor.
Set the tester to the "Resistance" mode, and measure
the resistance between the following terminals.
IC400-30 (P) - TM403(U) / TM404(V) / TM405(W)
IC400-24 (N) - TM403(U) / TM404(V) / TM405(W)
Judge the result of
as follows:
Terminal
Resistance value
Tester(+)
Tester(-)
P
U
P
V
P
W
U
P
V
P
W
P
N
U
N
V
N
W
U
N
V
N
W
N
Test 2 : Check the Transistor of PCB ( for Diode )
Set the tester to the "Diode" mode, and measure the voltage value between the following terminals.
Judge the result of
as follows:
Terminal
Tester(+)
Tester(-)
P
U
P
V
P
W
U
P
V
P
W
P
N
U
N
V
N
W
U
N
V
N
W
N
Over 2k
(Including
)
Over 20k
(Including
)
Over 2k
(Including
)
Tester display
0.3V
0.7V
02-58

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents