Download Print this page

Sharp SB-29S Service Manual page 7

Hot & cold water dispenser

Advertisement

1. Remove the terminal cover.
2. Remove the screw holding the power cord ass'y
3. Remove 2 closed terminal to power cord ass'y.
4. Now the power cord ass'y is free.
Compressor
Stand
1. Remove 5 screws holding the condenser ass'y.
2. Disconnect 2 terminals lead wire from thermostat.
3. Remove 2 screws holding the thermostat to the thermo fixing plate.
4. Now the thermostat is free.
1. Remove the thermostat in accordance with "REMOVE OF THERMOSTAT".
2. Disconnect the lead wire fuse.
3. Now the fuse is free.
REMOVE OF POWER CORD ASS'Y
Closed terminal
REMOVE OF THERMOSTAT
Screw
Thermo fixing plate
REMOVE OF FUSE ASS'Y
Screw
Thermo motor
Fig. 3
Fig. 4
7
Power cord ass'y
Cover strap
Terminal cover
PTC relay
Screw
Screw
Condenser ass'y
Thermostat
Terminal

Advertisement

loading

This manual is also suitable for:

Sb-29