ABB 8241 Operating Instructions Manual page 21

8240 series. modbus communication supplement
Table of Contents

Advertisement

...10.3 Single-stream Phosphate Monitor, Model 8242/185
...10.3.2 Holding Registers
Input Number
Read/Write
046
R
047
R
048
R
049
R
050
R/W
051
R/W
052
R/W
053
R/W
054
R/W
055
R/W
056
R/W
057
R/W
058
R/W
059
R/W
060
R/W
081
R/W
082
R/W
083
R/W
084
R/W
085
R/W
086
R/W
087
R/W
088
R/W
Description
Displayed Slope
Phosphate Concentration
Phosphate Concentration
Phosphate Concentration
Decimal Point Status
Current Output 1 Range
Current Output 2 Range
Alarm 1 Relay Setpoint
Alarm 1 Relay On/Off Status
Alarm 1 Relay Action
Alarm 2 Relay Setpoint
Alarm 2 Relay On/Off Status
Alarm 2 Relay Action
Alarm Relay Delay
Current Output 1 Hold Status
Current Output 2 Hold Status
Unit Type
Colour Compensation Applied
Colour Compensation Frequency
Next Colour Compensation
Next Colour Compensation
Next Colour Compensation
Next Colour Compensation
Next Colour Compensation
10 MODBUS COILS AND REGISTERS...
Response/Entry
0.0 to 100.0
Scaled 0 to 10.00 with 2 decimal places
Scaled 0 to 60.0 with 1 decimal place
0=1 dp, 1=2 dp
Scaled 0 to 20.0 or 0 to 60.0
Scaled 0 to 20.0 or 0 to 60.0
Scaled 0 to 20.0 or 0 to 60.0
0=Off, 1=On
Scaled 0 to 20.0 or 0 to 60.0
0=Off, 1=On
0=Low, 1=High
0 to 99 Minutes
0=No, 1=Yes
0=No, 1=Yes
0 = P, 1 = PO
4
Scaled 0.0 to 60.00
0=Off, 1=Man, 2=24hr, 3=12hr, 4=6hr, 5=3hr, 6=1hr
Date
Month
Year
Hour
Minute
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

8242

Table of Contents