30
en | Configuration
To default the control panel settings using the Installer Code:
1.
2.
3.
The control panel default factory settings are restored.
To restore the default control panel settings using the default button:
1.
2.
3.
4.
5.
The control panel default factory settings are restored.
Notice!
Do not connect the DLA to control panel when restore the default control panel settings using
the DEFAULT button, otherwise the control panel will start firmware upgrading.
2017.10 | 03 | F.01U.298.026
Enter the Installer Code (the default is 1234) and press [#] to enter Installer's
Programming Mode. Two beeps sound. The STAY and AWAY indicators flash to indicate
you entered Installer's Programming Mode.
Enter [9 6 1 #]. Two beeps sound after the default control panel settings are restored.
Enter [9 6 0 #]. The STAY and AWAY indicators stop flashing and the system returns to
the disarmed state.
Disconnect the AC MAINS supply and the backup battery from the control panel.
Press and hold the DEFAULT button.
Reconnect the AC MAINS supply to the control panel.
Wait 3 to 5 sec and release the DEFAULT button.
Enter [2580*] to disarm the system using the default Master Code.