Fujitsu AUYG07LVLA Design & Technical Manual page 187

Multi: 5, 6 rooms type
Hide thumbs Also See for AUYG07LVLA:
Table of Contents

Advertisement

¢ System diagram
1 remote controller:
Indoor unit
A
Remote controller
¢ Electrical wiring
1 remote controller:
Indoor unit
Remote
controller
1 2 3
1 2 3
Remote controller
¢ Controller combination
As for the combined usage of the controller, refer to following figures.
 Good
Indoor unit
UTY-RVNYM
2 remote controllers:
Indoor unit
B
C
Primary
Secondary
Remote controllers
1 (Red): 12 V
2 (White): Signal
3 (Black): COM
Indoor unit
UTY-RVNYM
UTY-RVNYM UTY-RNNYM
- 179 -
A, B, C: Remote controller cable
A ≤ 500 m;B + C ≤ 500 m
2 remote controllers:
Indoor unit
Remote
controller
1 2 3
1 2 3
1 2 3
Primary
Secondary
Remote controllers
Indoor unit
SET TEMP.
START/STOP
UTY-RVNYM UTY-RSNYM
1 (Red): 12 V
2 (White): Signal
3 (Black): COM

Hide quick links: