Model name
Power supply
Available voltage range
Capacity
Input power
Running current
Cooling
Airflow rate
Fan
Heating
Type × Q'ty
Motor output
Cooling
Sound pressure level *
Heating
Cooling
Sound power level
Heating
Dimensions (H × W × D)
Fin pitch
Heat exchanger type
Rows × Stages
Pipe type
Fin type
Material
Enclosure
Color
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Liquid
Size
Connection
Gas
pipe
Method
Material
Drain hose
Size
Cooling
Operation range
Heating
Remote controller type
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
ASYG07LMCE
kW class
2.0
W
15
A
0.13
HIGH
560
MED
500
LOW
430
QUIET
310
3
m
/h
HIGH
560
MED
500
LOW
430
QUIET
330
W
HIGH
36
MED
32
LOW
29
QUIET
21
dB (A)
HIGH
36
MED
32
LOW
29
QUIET
22
51
dB (A)
51
mm
mm
mm
kg
mm (in)
mm
°C
%RH
°C
- 17 -
ASYG09LMCE
ASYG12LMCE
1Ø 230 V ~50 Hz
198—264 V
2.5
3.5
17
22
0.15
0.19
600
660
520
560
430
450
310
310
600
660
520
560
430
470
330
330
Cross flow fan × 1
35
37
40
33
36
29
30
21
21
37
40
33
36
29
31
22
22
52
54
52
55
Main: 320 × 630 × 20
Sub: 84 × 630 × 13.3
Main: 1.1, Sub: 1.4
Main: 2 × 20, Sub: 1 × 4
Copper tube
Aluminum
Polystyrene
White
(Approximate color of Munsell N 9.25/)
270 × 870 × 204
270 × 925 × 336
8.5
11.0
Ø6.35 (Ø1/4)
Ø9.52 (Ø3/8)
Flare
PP + LLDPE
Ø13.8 (I.D.), Ø15.8 to Ø16.7 (O.D.)
18 to 32
80 or less
16 to 30
Wireless (Wired [option])
ASYG14LMCE
4.0
28
0.25
730
600
530
360
730
615
560
375
42
38
33
25
42
38
35
27
56
57
Ø12.7 (Ø1/2)