Index Parameter name /
value
84.06 INPUT1
-255.255.31 ...
+255.255.31 / C.-32768
... C.32767
84.07 INPUT2
-255.255.31 ...
+255.255.31 / C.-32768
... C.32767
84.08 INPUT3
-255.255.31 ...
+255.255.31 / C.-32768
... C.32767
84.09 OUTPUT
...
...
84.79 OUTPUT
85
USER CONSTANTS
85.01 CONSTANT1
-8388608 to 8388607
85.02 CONSTANT2
-8388608 to 8388607
85.03 CONSTANT3
-8388608 to 8388607
85.04 CONSTANT4
-8388608 to 8388607
85.05 CONSTANT5
-8388608 to 8388607
85.06 CONSTANT6
-8388608 to 8388607
85.07 CONSTANT7
-8388608 to 8388607
85.08 CONSTANT8
-8388608 to 8388607
85.09 CONSTANT9
-8388608 to 8388607
85.10 CONSTANT10
-8388608 to 8388607
85.11 STRING1
Description
Selects the source for input I1 of Block Parameter Set 1 (BPS1).
Parameter pointer or constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. The inversion field must have
value C to enable the setting of the constant.
Example: The state of digital input DI2 is connected to Input 1 as follows:
- Set the source selection parameter (84.06) to +.01.17.01. (The application
program stores the state of digital input DI2 to bit 1 of actual signal 01.17.)
- Invert the value by switching the sign of the pointer value (-01.17.01.).
See parameter 84.06.
See parameter 84.06.
See parameter 84.06.
See parameter 84.06.
Stores and displays the output of Block Parameter Set 1.
Stores and displays the output of Block Parameter Set 15.
Stores the output of Block Parameter Set 15. See parameter
Storage of the Adaptive Program constants and messages.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Sets a constant for the Adaptive Program.
Integer value.
Stores a message to be used in the Adaptive Program (EVENT block).
Actual signals and parameters in ACS800 Standard Application Program
FbEq
84.09.
37