Installation Configurations - Whirlpool Gold WFD193 Installation Instructions Manual

93 percent convertible multispeed gas furnace
Hide thumbs Also See for Gold WFD193:
Table of Contents

Advertisement

For installations above 7,000 ft (2,133.6 m), refer to your local
distributor for required kit(s).
Gas
Altitude
Kit
Natural
None #43
0 to
7,000 ft
Propane
LPM-
(2,133.6 m)
05
NOTE: In Canada, gas furnaces are only certified to 4,500 ft
(1,371.6 m).
Contact your local distributor for a tabular listing of appropriate
manufacturer's kits for propane gas and/or high altitude
installations. The indicated kits must be used to insure proper
furnace operation. All conversions must be performed by a
qualified installer or service agency.

Installation Configurations

This furnace may be installed in an upright position or horizontal
on either the left or right side panel.
NOTE: Do not install this furnace on its back.
For upright upflow furnaces, the return air ductwork may be
attached to the side panel(s) and/or base pan.
For horizontal upflow furnaces, the return air ductwork must be
attached to the base pan.
For both the upright or horizontal counterflow furnaces, the
return air ductwork must be attached to the base pan (top end of
the blower compartment).
NOTE: Do not attach the ductwork to the back of the furnace.
Contact your local distributor for the proper airflow requirements
and the number of required ductwork connections. See the
"Recommended Installation Positions" illustrations for the
appropriate installation positions, ductwork connections and the
resulting airflow arrangements.
Recommended Installation Positions—Upright Upflow
C
A. Air discharge
B. Alternate flue pipe location
Manifold
Pressure
Pressure
High
Low
Switch
Orifice
Stage
Stage
Change
3.5"
1.9"
None
W.C.
W.C.
#55
10.0"
6.0"
None
W.C.
W.C.
A
B
C
D
C. Side return duct connections
D. Bottom return duct connection
Recommended Installation Positions—Horizontal
Upflow—Left Side Panel Discharge
B
A
A. Air discharge
B. Alternate flue pipe location
C. Bottom return duct connection
Recommended Installation Positions—Horizontal
Upflow—Right Side Panel Discharge
A
A. Bottom return duct connection
B. Air discharge
Installation for Horizontal Applications
Horizontal applications dictate airflow direction, ductwork
connections and flue and combustion air pipe connections. The
basic application of this furnace as a horizontal furnace differs
only slightly from an upright installation. When installing a furnace
horizontally, additional consideration must be given to the drain
trap and lines, leveling the furnace, alternate vent/flue and
combustion air connections, alternate electrical and gas line
connections, the drain pan, freeze avoidance and furnace
suspension.
I
F
H
G
A. Alternate vent/flue location
B. Level end-to-end
C. Level side-to-side or slightly
tilted—doors 0" to ³⁄₄ " (1.9 cm)
below back panel
D. Drain line— ¹⁄₄ " (6.4 mm) per
foot downward slope
C
B
A
C
B
D
E
E. 24" (61 cm) minimum service
clearance
F. 4 ³⁄₄ " (12.1 cm) minimum drain trap
clearance
G. Supports at both ends and middle
H. Drain pan
I. Gas line with 3" (7.6 cm) minimum
drip leg
7