Issue 1.0
20
Figure 15 CM A7 SIP Trunk Control Channel Settings (continued)
1.
Select CCH assigned to SIP trunk and click the Read button to get
current data settings.
2.
YY=71 Select an unused SIP Trunk Profile Number.
3.
YY=77 Select this to send a manual registration.
This setting is not applicable for this carrier test leave at default.
4.
YY=78 Select Unit No. accommodating SIP trunk channels.
5.
Click Apply.
Command Line Example:
CM A771>01>00
CM A777>01>0
CM A778>01>01
Spectrum Enterprise
(SIP Trunk Profile 00)
(Sends a manual registration)
(Main Site Unit 01)
SIP Trunk Programming Guide