[Cma7] Ccis Channel Data/Ip Trunk Data/Sip Trunk Data - NEC UNIVERGE SV8300 Command Manual

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
A7
FUNCTION:
This command is used to assign the various data to each Common Channel Handler (CCH), IP Trunk
and SIP Trunk provided.
PRECAUTION:
When setting the IPT (P2P CCIS) No. with this command, be sure to set the first data to "00".
ASSIGNMENT PROCEDURE:
ST
+
+ DE
A7YY
DATA TABLE:
CCIS CHANNEL DATA
Y
No.
MEANING
00
Trunk used as Common Signaling
channel
01
Originating Point Code (OPC)
NOTE 1:
The Originating Point Code is used to designate an originating office in the No. 7 CCIS network.
A single OPC should be assigned to IPT No. 0 and all other IPT (P2P CCIS) provided in the same
office.
NOTE 2:
Do not change this data while the system is operating. If you do that, the operation of IP Stations
will be unstable.
02
Destination Point Code (DPC)
03
Centralized Billing Facility
CCIS CHANNEL DATA/IP TRUNK DATA/SIP TRUNK DATA
+
CCH/IPT/SIP TRUNK No. (00-15)
NONE
RESET
NONE
NONE
+
DE
SETTING DATA
DATA
MEANING
000
Trunk number assigned by CM10
Y=00
511
No data
00001
Originating Point Code
16367
No data
00001
Destination Point Code
16367
No data
0
Distant End is a Center Office
1
Distant End is a Local Office
3
Not provided
3-464
DATA
+
+
EXE
(1-5 digits)
RELATED
COMMAND
CM10 Y=00
Continued on next page
NWA-033623-001 Rev.3.0
CMA7
: Default
91ch3007.fm