NEC UNIVERGE SV8300 Command Manual page 273

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
35
(2) CM35 Y=290 (Setting of PAD data from a station to a trunk)
1st data =00-63 (Trunk route number)
2nd data=13 (3 dB loss)
(3) CM35 Y=291 (CODEC Filter Type)
1st data=00-63 (Trunk route number)
2nd data: see below
2ND DATA
01
TYPE1 [Very short distance]
13
TYPE3 [Long distance]
NOTE 1:
For a LDT/ODT blade, set the second data depending on the line distance of the line.
NOTE 2:
This command is effective for the data set for the trunk route of the base port of each
COT/LDT/ODT blade (All ports of the blade including COTDC become the same
setting).
NOTE 3:
For the second data, signal losses in the line distance of the line are estimated as
follows.
Second data: 01 (TYPE1 [Very short distance])....... 0 dB
• Control of PAD data from a trunk to a station (for DTI)
(1) CM35 Y=289 (Intra-office connection PAD)
1st data =00-63 (Trunk route number)
2nd data=24 (8 dB loss)
(2) CM35 Y=290 (Setting of PAD data from a station to a trunk)
1st data =00-63 (Trunk route number)
2nd data=NONE
TRUNK ROUTE DATA
For connecting to the behind PBX, TA and IP telephone adapter.
For the line is far from the Office PBX and the signal loss is large.
: 02 (TYPE2 [Middle distance])............. 4 dB
: 03 (TYPE3 [Long distance]) ................ 8 dB
(0 dB loss)
BLADE RESET
RECITAL
3-224
CM35
NWA-033623-001 Rev.3.0
91ch3003.fm
NOVEMBER/12/2008