NEC UNIVERGE SV8300 Command Manual page 348

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
43
Y
MEANING
6 Time setting for IP
Station firmware auto-
matic update
NOTE:
This data is recommended to set to have two minutes or longer interval of time from the system clock.
7 Start time for copying
the system data from
the Main Unit to
Remote Units
NOTE 1:
System data copy is executed from the low Remote Unit number to high Remote Unit number.
NOTE 2:
The start time for system data copy may gain/loss about three minutes from the time you set.
8 Time setting for
Automatic clock
change
PERIODIC MAINTENANCE/IP STATION FIRMWARE AUTOMATIC
UPDATE/SYSTEM DATA COPY/AUTOMATIC CLOCK CHANGE
1ST
MEANING
DATA
00
IP Station firmware
automatic update time
00
System data copy
00
Time setting for
automatic system clock
change from standard
time to daylight-saving
time
(for change pattern 0)
01
Time setting for auto-
matic system clock
change from daylight-
saving time to standard
time
(for change pattern 0)
2ND DATA
YYYY MM DD HH mm
NONE
HH MM
9999
NONE
MM W D
NONE
3-299
CM43
: Default
MEANING
YYYY: Year (2008-2099)
MM
: Month (01-12)
DD
: Day (01-31)
HH
: Hour (00-23)
mm
: Minutes (00-59)
No data
HH : Hour (00-23)
MM : Minute (00-59)
Not copy the system data
automatically
0200 (2:00 a.m.)
MM: Change Month (01-12)
W : Change Week (1-4/9)
First-Fourth Week
(1-4)
Final Week (9)
D
: Change Day of the
week (0-6)
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Automatic clock change is
not provided
Continued on next page
NWA-033623-001 Rev.3.0
91ch3004.fm
NOVEMBER/12/2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents