NEC UNIVERGE SV8300 Command Manual page 143

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
0B
Y
No.
MEANING
2XX 2 : VOIP Port
XX: Unit No. (01-50)
LAN DATA ASSIGNMENT
1ST DATA
DATA
MEANING
40
RTP Base Port for Voice
Packet transmitting/
receiving
NOTE:
The port number to be used for transmitting/receiving the RTP packets is
used at 2-port intervals from the Base port set by this command for each
channel.
For the default settings, the following port number is used.
CHANNEL No.
90
Provide the call log col-
lection with VoIPDB
NOTE:
When changing this data of VoIPDB accommodated in a Remote Unit,
execute the system data copy by CMEC Y=8 to the Remote Unit.
91
Provide the fault log col-
lection with VoIPDB
120
Tone Disabler for the
FAX communication on
the SIP trunk
NOTE:
Tone Disabler is a feature to improve FAX communication rate.
When detecting V.25 tone (2100 Hz) with phase inversion, Echo
Canceller/NLP (Non Linear Processor) is set to OFF. When detecting
V.25 tone (2100 Hz) without phase inversion, Echo Canceller/NLP (Non
Linear Processor) is set as same as voice setting.
121
DTMF inband mode for
VoIPDB
2ND DATA
DATA
01024
RTP Port number
65534
NONE
10000
RTP PORT No.
1
2
.
. .
128
0
To provide
1
Not provided
0
Not provided
1
To provide
0
Available
1
Not available
0
In-band mode (Voice pass
through)
1
Out-band mode (with
H.245 UII/RFC2833)
3-94
RESET
RELATED
COMMAND
MEANING
CMA7 Y=46
CMBA
Y=30, 93
10000
10002
.
. .
10254
Continued on next page
NWA-033623-001 Rev.3.0
CM0B
: Default
91ch3001.fm
JULY/18/2008

Hide quick links: