COMMAND CODE TITLE:
9B
FUNCTION:
This command is used to provide the event occurrence notice button. When the offices with CCIS via
IPT (P2P CCIS) connection SIP trunk connection are disconnected due to a fault occurrence, the link
down can be notified to the Multiline Terminals that are connected to the offices. Also the Units (except
Main Unit) are disconnected due to a fault occurrence, the link down can be notified to the Multiline
Terminals that are connected to the units.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
+ DE
+
ST
+
9BY
DATA TABLE:
Y
No.
MEANING
0
Link down notice
for CCIS/SIP
trunk/Units to the
Event Occurrence
Notice button
NOTE:
Link down notice (02-50) corresponds to the Unit No. 02-50 (except Main Unit).
EVENT OCCURRENCE NOTICE BUTTON ASSIGNMENT
EVENT OCCURRENCE NOTICE
BUTTON NUMBER
+
LINK DOWN NOTICE FOR
CCIS/SIP TRUNK/UNITS
(4 digits)
1ST DATA
DATA
MEANING
XX ZZ XX: 01-64: Event
Occurrence
Notice Button
No.
ZZ : 00: Link down
notice for CCIS
02-50: Link
down notice for
Units (except
Main Unit)
51: Link down