COMMAND CODE TITLE:
AC
FUNCTION:
This command is used to assign the functions to the BRT blade.
PRECAUTION:
This command requires system reset after data setting.
ASSIGNMENT PROCEDURE:
ST +
DE
ACYY
+
DE
ST +
AC30
+
SPID
+
EXE
(4 digits)
DATA TABLE:
Y
No.
MEANING
00
ISDN Line station number to be con-
trolled
01
Layer 2 data link
03
Passive Bus in Point-to-Multipoint con-
nection
06
Checking of TEI (Terminal End-point
Identifier) when Layer 2 data link is
released
10
National ISDN-1 mode
[North America Only]
11
Sending of expanded information on
Low Layer Compatibility (LLC) infor-
mation element for connection between
ISDN telephone/ISDN trunks
ISDN FUNCTIONS
ISDN
+
D-CHANNEL No.
(00-31)
TRUNK BLADE No.
+
(000-127)
XXXXXXXX
ISDN
+
MULTIPOINT No.
+
(0-7)
ISDN
+
MULTIPOINT No.
(0-7)
SETTING DATA
DATA
MEANING
X
ISDN Line station number
0
Point-to-Point connection
1
Point-to-Multipoint connection
0
Extended Passive Bus
1
Short Passive Bus
0
To provide
1
Not provided
0
To provide
1
Not provided
0
Allow
1
Restricted
3-474
DATA
DE
+
+
(1-8 digits)
ISDN
DE
SUBSCRIBER No. +
+
+
(4 digits)
RELATED
COMMAND
CM08>722
CM35 Y=130
Continued on next page
NWA-033623-001 Rev.3.0
CMAC
RESET
EXE
: Default
91ch3007.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents