Burner Selection; Conditions Power Supply - Bosch Uni 5000F US Installation And Service Instructions Manual

Low-temperature oil and gas-fired boiler
Hide thumbs Also See for Uni 5000F US:
Table of Contents

Advertisement

2.8.5

burner selection

Oil burner
boiler size
Uni 171
Uni 207
Uni 256
Uni 171
Uni 207
Uni 256
Uni 171
Uni 207
Table 9
Oil burner
Gas burner
burner
boiler size
manufacturer
Uni 171
Riello
Uni 207
Uni 256
Table 10 Gas burner
2.8.6

Conditions power supply

Operating conditions
Power supply voltage
Fuse
Frequency
Protection
Table 11 Power supply
burner manufacturer
Riello
Bekett
Carlin
burner model
40G200
40G400
40G400
Notes – Requirement in greater detail
110−120 V
Observe the voltage range of the burner and controls used. The outer casing/boiler must be
grounded for safety reasons and in order to function correctly.
10 A
60 Hz
Sinusoidal voltage curve
IP 40 (protected against contact by entry of foreign objects > 0.04 inches Ø
(> 1 mm Ø ), no water proofing)
burner model
40F5
40F10
40F10
AFG
CF375
CF375
99 FRD
99 FRD
orifice
natural
propane
2.00 mm
1.30 mm
2.20 mm
1.50 mm
2.20 mm
1.50 mm
Product description | 13
nozzle
1.25 x 80 B
1.50 x 80 W
1.75 x 45 B
H 1.10 x 45 ES
H 1.35 x 45 ES
H 1.75 x 45 ES
D 1.25 x 60 B
D 1.50 x 60 B
manifold pressure
natural
1.75" WC
(436 Pa)
0.95" WC
(236.5 Pa)
1.30" WC
(323.5 Pa)
6 720 648 162 (2011/08)
pump pressure
145 Psi
(10 bar)
145 Psi
(10 bar)
185 Psi
(12,75 bar)
175 Psi
(12 bar))
170 Psi
(11,7 bar)
140 Psi
(9,6 bar)
150 Psi
(10,3 bar)
150 Psi
(10,3 bar)
propane
2.60" WC
(647 Pa)
1.30" WC
(323.5 Pa)
1.70" WC
(423.5 Pa)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uni 171Uni 207Uni 5000f caUni 256

Table of Contents