2 million imp. maintenance (continued)

Utility cabinet
Chiller unit
Inline densitometer
Lubrication
CA294-00570
2 Million Imp - Preventive Maintenance Guide - HP Indigo press 5000
Clean the lower feed roller and pinch rollers (IFR) with
IPA.
Check the duplex conveyor-impression drum gap, and
adjust, if necessary.
Replace perfector suction cups.
Clean Stacker paper path with IPA.
Check Stacker flipping wheels.
Check that the paper buckle is correct. Adjust if
necessary.
Perform the suction cup margin adjustment wizard.
Perform the full placement adjustment wizard.
Check oil level in solid air compressor.
Clean vacuum pump filters. See "Appendix B -
Vacuum pump maintenance" on page 14.
Drain water separator - open service valve for 30
seconds.
Check water level.
Clean the water filter, and replace, if needed. See the
chiller manual.
Print a new reference densitometer full calibration
strip if one is not available, and perform the validation
procedure. See the HP Indigo service instruction for
the Inline Densitometer.
Instruct the operator to store the strip in a dark, clean
place.
Make sure that all lubrication points have been oiled
and greased properly, including the exit elevator
gears and chains. See "Appendix C - Grease and oil
types" on page 17. For a complete list, check the
User Guide, or view the press On-line documentation
videos (OPD).