1.4 Specifications — KX-TDA100/KX-TDA200
1.4
Specifications — KX-TDA100/KX-TDA200
1.4.1

General Description

Control Bus
Communication Bus
Switching
Power Input
External Battery
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Conference Call Trunk
Music on Hold (MOH)
Paging
Serial Interface Port
30
Installation Manual
Original bus (16-bit, 8 MHz, 10 megabytes per second)
H.100 bus conformity (1024 time slot)
Non-blocking
PSU-S
100 V AC to 130 V AC, 1.4 A/200 V AC to 240 V AC, 0.8 A,
50 Hz/60 Hz
PSU-M
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A,
50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A,
50 Hz/60 Hz
+36 V DC (+12 V DC × 3, battery capacity of 28 Ah or below
recommended for each external battery)
300 ms (without using backup batteries)
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
From 10 × 3-party conference call to 4 × 8-party conference
call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (maximum 115.2 kbps)
USB
1
maximum

Hide quick links: