Download Print this page
ABB LM80 Quick Installation Manual

ABB LM80 Quick Installation Manual

Laser level sensor

Advertisement

Quick Links

Quick Installation Guide QG/LM80CA-EN Rev. B
LM80
Laser Level Sensor
Intermediate Range Laser Level Sensor
– Range up to 100m for level applications
– Range up to 150m for positioning
– Resolution 10 mm
– Operating temperature -40°C to +60°C
Refer to the LM80 data sheet and user guide for complete specifications at:
http://www.abb.com/level
Standard Precautions
– Read the LM80 user guide safety information section before installing or using the LM80
– Do not drop the instrument or expose the internals to water and dirt
– Do not open the terminal compartment in a possible explosive atmosphere
– Do not install or connect with the power on
– Use appropriate insulated lugs or ferrules with stainless washers for connections
– Keep the terminal compartment seal clean and lightly lubricated with Vaseline®
– Ensure that the terminal compartment lid, cable gland or conduit are tight after installation
– Only use glands that have been suitably certified by a notified body
– Do not install conduit so that it can drain into the LM80 terminal compartment
– Remove dirt from the lenses with a clean, damp cloth only
– Aim perpendicular to liquids and avoid aiming into the vessel fill path or at the sun

Laser Safety

Measuring laser always on IEC60825-1 class 1M laser
A class 1M laser is safe for all conditions of use except when passed through magnifying optics. This
means the maximum permissible exposure cannot be exceeded when viewing the laser with the naked
eye without the aid of magnifying optics.
Red pointing laser intermittent IEC80825-1 class 3R laser
Laser comes on at power up for 2 minutes, it can be turned back on for commissioning using the
LCD2 communications and configuration device.
A class 3R laser is considered safe if handled carefully, with restricted beam viewing. With a class 3R
laser the maximum permissible exposure can be exceeded when viewing the laser with the naked eye,
but with a low risk of injury.

Advertisement

loading

Summary of Contents for ABB LM80

  • Page 1: Laser Safety

    Standard Precautions – Read the LM80 user guide safety information section before installing or using the LM80 – Do not drop the instrument or expose the internals to water and dirt – Do not open the terminal compartment in a possible explosive atmosphere –...
  • Page 2 Typical LM80 installation with dust tube (P801) and flange Typical LM80 24V DC electrical installation Refer to user guide for more information 24 v DC power supply 100 Ω 60 Ω 60 Ω 60 v DC or 250 v AC power supply 90 mm (3.54 in)