1.2.2. Remote Lockout
Use the handheld programmer to enable or disable programming via the network
and PDM.
Hand
programmer
values
1.2.3. Factory Reset
Following a Master Reset, complete reprogramming is required.
Note:
Hand
programmer
values
Open the menu Device – Master Reset and select one of the four options.
1.2.4. Reset Fault
Resets the Fault message after an active fault has occurred and been corrected.
A manual reset is required only for the following faults:
Hand
programmer
values
Open the menu View – Clear Faults, and select the fault in question from the pull-
down menu for Extended Diagnostics.
(To reset via the handheld programmer, key in the value of the fault code in
question.)
1.2.5. Menu Timeout (default 120 s)
Determines the length of time (in seconds) the device will stay in PROGRAM mode
without any key presses occurring.
1.3. Device
Manufacturer
References a specific manufacturer, usually the name of the company
responsible for the manufacture of this Field Device.
Page 74
SITRANS Probe LU (PROFIBUS PA) – INSTRUCTION MANUAL
0
*
Unlocked
1
Locked
Reset all parameters (except PROFIBUS address) to
1
PROFIBUS PA profile default values
2506
Warm Start: restart the device (this option is rarely used)
2712
Reset PROFIBUS address to 126
32768 Reset to manufacturer's default values (factory settings)
12
Internal temperature high
Transducer temperature high
Transducer temperature low