2.6.3 Installation on Clarus Control

The cable from the RJ11 port on the EDS controller shall be connected to the X10 connection on the CPU card A1
CPU card A1 has different locations depending on machine model.
Follow the instruction for your type of machine.
W465H/N/S-W4330H/N/S
Disconnect the power to the machine.
The cable from the RJ11 port on the EDS controller shall be run through a hole at the back of the machine (A) and
connected to the X10 connection on the CPU card A1.
Insert the cable and mount with the counter nut and cable gland according to the figure.
fig.W01145
Demount the top panel and remove the cover over the connection module.
Locate the X10 connection on back right side on the CPU card A1.
Connect the cable from the RJ11 port on the EDS controller to the CPU card A1.
Strap the cable at suitable positions. The cable must not be in contact with the drum.
fig.5207A
W4400H-W41100H
Disconnect the power to the machine.
Open the electric cabinet on the back of the machine.
Locate the X10 connection on the CPU card A1.