Connecting Up; Preparing The Pidu Plus To Odu Cable; Integral Safety Loop - Motorola PTP 300 Series User Manual

Motowi4 series
Hide thumbs Also See for PTP 300 Series:
Table of Contents

Advertisement

Installation
The enclosure and mounting brackets of the PTP 300 Series Bridge product range are capable of
withstanding wind speeds up to 200 mph (320 kph). The installer should ensure that the structure
the bridge is fixed to is also capable of withstanding the prevalent wind speeds and loads. See
Section 12
"Wind Loading".
The integral safety loop should be used both for hoisting the ODU up a mast or building and into
position, and also as a fixing point to secure a permanent safety lanyard from the tower/building
to the ODU in case of mounting failure.
Figure 15 Integral Safety Loop
The length of the safety lanyard must not exceed 1m (approx 3 ft) in length. The lanyard should
be made from a material that does not degrade in an outdoor environment.
The safety lanyard must be fixed to a separate fixing point that is not part of the direct mounting
system for the ODU.

7.7 Connecting Up

7.7.1 Preparing the PIDU Plus To ODU Cable

Note: The maximum cable length between the ODU and the user's network equipment is 100m
(330 ft). The cable should be assembled as shown in
Figure
16.
48

Advertisement

Table of Contents
loading