All of the above attributes are non-volatile, once set they will be used by the unit even after a power
on reboot. A number of attributes, such as IP Address, Subnet Mask and Gateway IP Address and
VLAN settings will require a reboot before they are used. If any of these attributes are changed a
reboot screen appears asking the user to verify the reboot
This will be followed by a pop-up dialogue box asking to confirm the action.
Note: At this point you will lose connection to the unit. If you have just changed the IP Address
you now have to reconnect to the unit using the address just set.
8.3.1.3 LAN Configuration Page – Use VLAN For Management Interfaces
The layout of the LAN Configuration page changes if this attribute is enabled in order to allow the
VLAN VID and VLAN Priority to be set, see
after the unit is rebooted.
Caution: You must ensure that you can access the VLAN which you configure here, otherwise
you will be unable to access the unit following the next reboot.
Caution: The PTP 300 management function is only compatible with single VLAN tagged packets.
Any management packet with two or more tags will be ignored.
Web Page Reference
Figure 32 Configuration Reboot Page
Figure 33 Configuration Reboot Page – Ethernet Auto Nego-
tiation Disabled
(Figure 32
Figure
34. The VLAN settings are applied only
71
or
Figure
33).