Device Designs - ABB LME620-AI User Manual

Electronic unit for field installation for the control of contrac control actuators series pme, lme, rhd and rsd
Hide thumbs Also See for LME620-AI:
Table of Contents

Advertisement

8
LME620-AI / PME120-AI / EAN823 / EBN853 / EBN861 ELECTRONIC UNIT | OI/PME/LME/EAN823/EBN853/EBN861-EN REV. E
... 2 Design and function

Device designs

EAN823
IP rating
Humidity
Ambient temperature
Transport and storage temperature
Long-term storage temperature
Mounting position
Vibration stress
Electrical connection
Weight
EBN853
IP rating
Humidity
Ambient temperature
Transport and storage temperature
Long-term storage temperature
Mounting position
Vibration stress
Paint
Electrical connection
Weight
IP 66 in accordance with IEC 60529 / EN 60529
NEMA 4X in accordance with CAN / CSA22.2 No. 94
≤ 95% annual average; condensation not permitted
−25 to 55 °C (−13 to 131 °F)
−25 to 70 °C (−13 to 158 °F)
−25 to 40 °C (−13 to 104 °F)
On vertical mounting plate, lateral cable gland, left
Maximum 150 Hz: acceleration: 1 g (in accordance with EN 60068-2-6, Table C.2)
Mains supply and connection cable to the control system through screw terminals.
Connection cable between electronic unit and actuator tightly fastened optionally to the electronic unit,
from the actuator side using a connector to the connection to the actuator. Available cable lengths 5 m
(16 ft), 10 m (32 ft) or 20 m (65 ft).
Maximum cable length for delivery without cable: 30 m (98 ft)
11 kg (24 lbs)
IP 66 in accordance with IEC 60529 / EN 60529
NEMA 4X in accordance with CAN / CSA22.2 No. 94
≤ 95% annual average; condensation not permitted
−25 to 55 °C (−13 to 131 °F)
−25 to 70 °C (−13 to 158 °F)
−25 to 40 °C (−13 to 104 °F)
On vertical mounting plate, lateral cable gland, left
Maximum 150 Hz: acceleration: 1 g (in accordance with EN 60068-2-6, Table C.2)
2-layer component epoxy (RAL 9005, black)
Mains supply via screw terminals; all other connections made via screw-type plug connectors
Connection cable between electronic unit and actuator tightly fastened to the electronic unit, from the
actuator side using a connector to the connection to the actuator. Maximum cable length 100 m (328 ft).
In actuators in explosion-proof design, the connection cable is tightly fastened to the actuator without a
connector through the screw terminals.
Optional, loose cable set supplied acc. to length requirements
11 kg (24 lbs)