500ML Lighting Control Console
The LEDs above the [CLEAR] and the [I], [F], [C] and [B] buttons indicate the current state of the values:

Assigning Values to Fixture Attributes

500ML Lighting Control Console segregates common fixture parameters into four groups:
• [I] - Intensity Parameter (Dimmer, strobe, duration, etc.)
• [F] - Focus Parameters (Pan / Tilt position)
• [C] - Color Parameters
• [B] - Beam Parameters (Gobos, Zoom, Focus, etc)
Note: Remember, the programmer takes precedence over the underlying playback. Press the [CLEAR] key three
times to empty the programmer contents.

Altering Intensity (Dimmer Values) Using Multifunction Wheel

The Multifunction (dimmer) wheel on the right hand side of the console faceplate (as indicated in
can be used to increment up or decrement down the dimmer values of the selected fixtures.

Altering Intensity (Dimmer Values) Using Keypad

Numerical dimmer values (levels) may be applied directly to selected fixtures using the command line interface by
typing [@] followed by either [FULL] or the intensity value (in percent) followed the [ENTER] key.
Keypad Syntax
Keypad Entry
[@] [.] [VALUE]
[VALUE A] [THRU] [VALUE B]
[VALUE A] [THRU] [THRU] [VALUE B]
LED Color
Green
Yellow
Red
Figure 37: Clear and IFCB Buttons
Table 2: Keypad Value Syntax Entry
[@] [FULL]
Will set the selected fixtures to 100%
[@] [@]
Will set the selected fixtures to 100%
Will set the selected fixtures Intensity DMX Value to [VALUE]
Will fan the Intensity for selected fixtures from [VALUE A] to [VALUE B]
For Example: [0] [THRU] [100] with 3 selected fixtures will set fixture 1 to 0%, fixture 2 to 50%
and fixture 3 to 100%.
Will fan the Intensity for selected fixtures from [VALUE A] to [VALUE B] and back to [VALUE A].
For Example: [0] [THRU] [THRU] [100] with 5 selected fixtures will set fixture 1 and 5 to 0%,
fixture 2 and 4 to 50% and fixture 3 to 100%.
State
Fixtures are selected (Only applies to [CLEAR] key)
There are values in the programmer and the corresponding attribute group
There are modified (touched) values in the programmer and the
corresponding attribute group that may be recorded
Meaning
QuickStart Guide
Figure 1 on page
5)
27
Working with Values

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

500ml

Table of Contents