4.10 Network Example Diagram - Siemens SINAUT MD740-1 User Manual

Table of Contents

Advertisement

4.10 Network example diagram

The following diagram shows how the IP addresses could be distributed in a local
network with subnets, which network addresses result and what the specification of an
additional internal route could be in the SINAUT MD740-1.
External IP: 192.168.11.2
Internal IP: 192.168.15.254
Network mask: 255.255.255.0
Router
Router
External IP: 192.168.15.1
External IP: 192.168.15.1
Internal IP: 192.168.27.254
Network mask: 255.255.255.0
= Additional internal routes
SINAUT MD740-1
GPRS/Internet
Address from outside: 80.81.192.37
(allocated by Provider)
TAINY GMOD-V2-IO
Internal address: 192.168.11.1
Router
Configuration
Net A
Netw. address: 192.168.11.0/24
Network mask: 255.255.255.0
Net B
Netw. address: 192.168.15.0/24
Network mask: 255.255.255.0
Net C
Netw. address: 192.168.27.0/24
Network mask: 255.255.255.0
81 von 105