Performance; General Specifications - Mitsubishi Electric A960GOT User Manual

Human machine interface, graphical operator terminal
Table of Contents

Advertisement

3 PERFORMANCE

3 PERFORMANCE

3.1 General Specifications

Item
Operating ambient
temperature
Storage ambient
3
temperature
Operating ambient
humidity
Storage ambient
humidity
Vibration
resistance
Shock resistance
Operating
atmosphere
Operating altitude
Installation site
Overvoltage category
2
Contamination level
3
1: For A975GOT-TBA/TBD (-B) and A970GOT-TBA/TBD (-B), it becomes 0 to 55°C.
2: Indicates the element in the distribution system between the public electricity grid and the mechanical
equipment inside the premises that the relevant device is assumed to be connected to.
Category II applies to devices such as those that draw their power supply from fixed installations.
The surge voltage withstand capability of devices with ratings up to 300V is 2,500V.
3: This index gives a measure of the incidence of conductive materials in the environment in which the device
is used.
A contamination level of 2 indicates an environment in which there is only contamination by non-
conducting materials, but due to occasional condensation, conductivity may occur.
4: Please do not use or store GOT in an environment with atmospheric pressure greater than the
atmospheric pressure at sea level (0m).
There is a possibility errors may occur if this point is not observed.
3 - 1
The general specifications of the GOT are indicated below.
Display section
Other than display
section
In case of
Conforms
intermittent
to JIS B3501
vibration
and IEC
In case of
61131-2
continuous
vibration
Conforms to JIS B3501, IEC 61131-2 (147 m/s
Specifications
0 to 40°C
0 to 55°C
-20 to 60°C
10 to 90 % RH, non-condensing
10 to 90 % RH, non-condensing
Frequency
Acceleration
10 to 57 Hz
2
9.8 m/s
57 to 150 Hz
10 to 57 Hz
2
4.9 m/s
57 to 150 Hz
2
, 3 times in each of X, Y and Z directions)
No corrosive gas
2000 m (6562 ft) max.
Inside control box
II or less
2 or less
MELSEC-GOT
1
Amplitude
Sweep Count
0.075 mm
10 times in
each of X, Y
and Z
0.035 mm
directions (for
80 minutes)
3 - 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A970gotA975gotA985got

Table of Contents