Motor Application - ABB REX640 Product Manual

Hide thumbs Also See for REX640:
Table of Contents

Advertisement

REX640
Product version: 1
been selected as well. Best match for current and voltage
measurement can be managed by selecting two AIM2 cards for
the relay. This combination offers 12 current and 8 voltage
channels to be freely allocated for the relay functionalities. The
OLTC control function requires information on the tap-
3I
Io
SM
RTD
3I
GUID-EF50EACA-C47D-4F0A-A1FA-935A94282DF6 V2 EN
Figure 9.

Motor application

Figure 9
presents REX640 in a synchronous motor application.
The base functionality is enhanced with a machine protection
application package and the related synchronous machine
12
REX640
PROTECTION AND CONTROL RELAY
Example of a combination of application packages for motor protection
PROTECTION
Master Trip
94/86
3U<
U1<
3U<R
3I<
27
27PS
27R
37
I2/I1>
3Ith>F
3I>/Io>BF
49F
46PD
50BF
Io>>
Io>
3I>>>
3I>
51G/
51G/
51P-1
50P
51N-2
51N-1
3U>
3I(U)
Uo>
U2>
59
51V
59G/59N
59NS
3I>→
3I>>→
Io>→
Io>>→
67P/
67G/N-1
67G/N-2
67P/
51P-1
51G/N-1
51G/N-2
51P-2
12×
3I2f>
f>/f<,df/dt
UFLS/R
68HB
81
81LSH
24×
CVPSOF
dIoLo>
ARC
MAP
AFD
SOFT
87NLI
MAP
APPLICATION PACKAGE FOR MACHINE PROTECTION
I2>>
3I<
I2>M
P>/Q>
37
46M
46R
32R/32O
Is2t n<
Ist>
49,66,48,50TDLR
50TDJAM
dHi_A>
dHi_B>
dHi_C>
3dl>M/G
87M/87G
87A
87B
87C
ADD-ON PACKAGE FOR SYNCHRONOUS MACHINE PROTECTION
X<
Z< G
U/f>
P<
21G
24
32U
40
3Ith>T/G/C
PF<
Io>R
49T/G/C
55U
64R
dUo>/Uo3H
OOS
64TN
78PS
changer's actual position. To be able to provide this
information, the relay is equipped with an RTD card which can
measure the OLTC position either as a resistance value or as an
mA signal.
LOCAL HMI (OPTIONAL)
I2>M
46M
- 7-inch color touch screen
Io>>>
- Ready-made pages and
50G/50N
customizable pages
- Increased situational awareness
towards process
- Supports Relay testing and
3I>>
commissioning
51P-2
- Graphical editing of pages with
PCM600 tool
U1>
59PS
CONDITION MONITORING
AND SUPERVISION
I2>→
67Q
CBCM
dIoHi>
MCS 3I
52CM
87NHI
CCM
TCS
OPTS
TCM
OPTM
CONTROL AND INDICATION
Object
3Ith>M
49M
CB
DC, 3 state
DC
n<
66
ES
Control and status indication function for
1)
primary object
3dIHi>M
Status indication function for primary
2)
87HIM
object
APP7
25AU-
SYNC
TOSYNC
25
ESTART
EST,62
REMARKS
Total nr. of instances
ADD1
add-on package. Best match for current and voltage
measurement can be managed by selecting both AIM1 and
AIM2 cards for the relay. This combination offers 11 current and
1MRS759144 A
ALSO AVAILABLE
- Disturbance and fault recorders
- Sequence event recorder
- Relay self-supervision
- User management and logging
- Logical and mathematical functions
- WebHMI
COMMUNICATION
Protocols:
IEC 61850-8-1/-9-2LE
Modbus
®
IEC 60870-5-103
DNP3
Interfaces:
Ethernet: TX (RJ45), FX (LC)
Serial:
Serial glass fiber (ST),
RS-485
Redundant protocols:
HSR
PRP
Time synchronization:
SNTP
PTPv2
IRIG-B
FUSEF
VCM, 60
MEASUREMENT
- I, U, Io, Uo, P, Q, E, pf, f
- Sequence current/voltage measurement
- Limit value supervision
- RTD/mA measurement and mA output
Analog interface types
Current transformer
Ctrl
Ind
1)
2)
Voltage transformer
3
-
RTD measurement
6
6
mA input/output
8
8
1)
One of available current transformer
3
3
inputs is sensitive (0.2/1 A)
LOADPROF
LOADPROF
O→I
PQM3IH
79
PQM ITHD, IDC
PQM3VH
PQM VTHD, VDC
APP7
PQMU
PQMV SWE,SAG,
INT
PQUUB
PQMV UB
AND
OR
1 0 1 0 0 0 1 1 0 0 1 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
1 0 1 0 0 0 1 1 0 0 1 1 0 0 1 0 1 0 0
1 0 1 1 0 0 1 0 1 1 1 0 0 1 0
1 1 0 0 1 1 1 0 1 1 0 1 0
1 0 1 1 0 1 1 0 1 1 0 1 0 0
AIM1 + AIM2
+ RTD1
11
1)
9
10
2
ABB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents