Mounting

4.2 Types of installation

Safety notices when using the device according to ATEX
If you use the device under ATEX conditions you must also keep to the following safety
notices in addition to the general safety notices for protection against explosion:
To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of
at least IP54 in compliance with EN 60529.
If the cable or conduit entry point exceeds 70 °C or the branching point of conductors
exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air
ambient in excess of 60 ℃, only use cables with admitted maximum operating temperature
of at least 80 ℃.
Further notes
NOTICE
Warming and premature aging of the network component due to direct sunlight
Direct sunlight can heat up the device and can lead to premature aging of the network
component and its cabling.
Provide suitable shade to protect the network component against direct sunlight.
4.2
Types of installation
Types of installation
The SCALANCE XC100-4OBR can be installed in the following ways:
● DIN rail
● S7-300 standard rail
● S7-1500 standard rail
32
WARNING
WARNING
Operating Instructions, 10/2013, C79000-G8976-C297-02
SCALANCE XC100-4OBR