Servicing The Transmission Fluid; Servicing The Auxiliary Hydraulic Fluid - Toro 29517 Operator's Manual

24in stand-on aerator
Hide thumbs Also See for 29517:
Table of Contents

Advertisement

4
Servicing the Transmission
Fluid
No Parts Required
Procedure
Transmission fluid type: Toro Hypr-oil 500
The machine is shipped with transmission fluid in the
expansion tank.
1.
Run the machine for approximately 15 minutes
to purge any extra air out of the transmission
system.
2.
Completely raise and lower the tines 3 times to
purge the air.
3.
Shut off the engine, engage the parking brake,
wait for all moving parts to stop, and remove
the key.
4.
Allow the engine to cool.
5.
Carefully clean the area around the front
of the fill cap; it is important that no dirt or
contamination enter the transmission system.
6.
Remove the cap and check the transmission-fluid
level in the expansion tank
Note:
The transmission-fluid level should cover
the FULL COLD line molded into the side of the
tank.
1. Cap
2. Filler neck (expansion
tank)
(Figure
3).
Figure 3
3. FULL COLD line
7.
If necessary, add the specified transmission
fluid until the level reaches the FULL COLD line
located on the reservoir tank.
Note:
If the fluid is at ambient-air temperature,
about 24°C (75° F), fill only to the FULL COLD
level.
8.
Install the reservoir cap and tighten it until snug.
Important:
cap.
9.
Start the engine and raise and lower the tines.
Lower the tines to the ground and refill the
reservoir to the FULL COLD line.
10.
Check the fluid level again; repeat steps
through
10
5
Servicing the Auxiliary
Hydraulic Fluid
No Parts Required
Procedure
Hydraulic fluid type: AW-32 hydro fluid
Note:
The machine is shipped with hydraulic fluid
in the reservoir.
1.
Run the machine for approximately 15 minutes
to purge any extra air out of the hydraulic
system.
2.
Completely raise and lower the tines 3 times to
purge the air.
3.
Shut off the engine, remove the key and allow
the machine to cool.
4.
Remove the cap and check the hydraulic-fluid
level in the reservoir.
Note:
The hydraulic-fluid level should cover
the word FULL COLD that is embossed into the
baffle of the reservoir.
5.
If necessary, add the specified hydraulic fluid
to the reservoir until the fluid covers the FULL
COLD fluid level on the baffle.
Note:
If the fluid is at ambient-air temperature,
g025891
about 24°C (75° F), fill only to the FULL COLD
level.
6.
Install the hydraulic reservoir cap and tighten it
until snug.
Note:
Do not overtighten the reservoir cap.
13
Do not overtighten the reservoir
until the level does not decrease.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

39517

Table of Contents