Table 5-13 lists the test conditions and results of the mechanical reliability of the
MU739 module.
Table 5-13 Test conditions and results of the mechanical reliability of the MU739 module
Item
Low-temperature
storage
High-temperature
storage
Low-temperature
working
High-temperature
working
Damp heat cycling
Temperature shock
Issue 01 (2011-08-24)
Test Value
155
230
In idle mode, the module is registered to the network, USB bus is active, and no voice or
data call connection is ongoing.
The above values are the average of some test samples.
Test Condition
Temperature: –40ºC ± 2ºC
Test duration: 24 h
Temperature: 85ºC ± 2ºC
Test duration: 24 h
Temperature: - 30ºC ± 2ºC
Test duration: 24 h
Temperature: 75ºC ± 2ºC
Test duration: 24 h
High temperature: 55ºC ± 2ºC
Low temperature: 25ºC ± 2ºC
Humidity: 95%
Repetition times: 4
Test duration: 12 h + 12 h
Low temperature: - 40ºC ± 2ºC
High temperature: 85ºC ± 2ºC
Temperature change interval: < 30s
Test duration: 15 min
Repetition times: 100
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Electrical and Reliability Features
Units
PCL
Configuration
2 Up/1 Down
4 Up/1 Down
Standard
IEC60068
IEC60068
IEC60068
IEC60068
IEC60068
IEC60068
55