TARGET SYSTEM CONNECTION TEST

The S5U1C33001H can diagnose whether it can communicate with the target system or not when the debugger (gdb.exe)
starts up. This function can be omitted or executed using the DIP switch.
• Omitting the target system connection test
If SW6 of the DIP switch located on the S5U1C33001H front panel is placed in the ON (lower) position, the
S5U1C33001H omits the target system connection test when the debugger (gdb.exe) starts up.
• Executing the target system connection test
If SW6 of the DIP switch located on the S5U1C33001H front panel is placed in the OPEN (upper) position, the
S5U1C33001H executes the target system connection test when the debugger (gdb.exe) starts up.
When the target system connection test is completed normally, the following is displayed on the debugger screen:
Connecting with target ... done
CPU type and debug unit address setting ... done
Initializing ............. done
CPU type and debug unit address setting ... done
CPU cold resetting ....... done
Target connection test ... done
ICD hardware version
ICD software version
CPU type and debug unit address setting ... done
CPU cold resetting ....... done
Boot address ............. 0xc00000
Note: Always be sure to turn off the power to the S5U1C33001H before setting the DIP switch.
If an error message is displayed after the target system connection test is executed, failure may have oc-
curred in the target system. Check to see whether the target system is working properly or not.
Normally enable the target system connection test.
← display when terminated normally.
... 30
("omitted" will appear if the connection test is omitted.)
... 3.5
S5U1C33001H
(Ver. 4)