Parameter Definitions - V500 Series; Outline Of Pnu - Mitsubishi Electric FR-A5NPA Instruction Manual

Profibus/dp communication option
Table of Contents

Advertisement

8. PARAMETER DEFINITIONS - V500 SERIES

8.1 Outline of PNU

You can use the PNU to make inverter settings from the network.
The data used with the network is denoted PNU(P) to differentiate it from
the parameter (Pr.).
CAUTION
The parameter definitions differ between the FR-V500 and A500/
F500 series. When using the A500/F500 series, refer to page 47.
(1) PNU data definition
P1902.1
Sub-Index number*
PNU number
* When the data type is "with array", the Sub-Index number is included in
the PNU.
(2) PNU data type
The PNU has the data types of "Array Unsigned 16" and "Unsigned
16".
Array Unsigned 16
P1902.1
Sub-Index number
Unsigned 16
P1200
CAUTION
When the data type is "with array", include the Sub-Index number in
the PNU.
Abbreviation:
AUs16
Abbreviation:
Us16
56
With array
Without array