Pr.
PNU
Name
Number
No. 1
P1918.1
terminal
gain (speed)
918
No. 1
P1918.2
terminal
gain (%)
No. 1
terminal
P1919.1
bias
(torque)
919
No. 1
P1919.2
terminal
bias (%)
No. 1
P1920.1
terminal
gain (torque)
920
No. 1
P1920.2
terminal
gain (%)
PARAMETER DEFINITIONS - V500 SERIES
Minimum
Setting Range
Setting
Decimal
Increments
1r/min
0 to 3600
0.1%
-
0.1%
0 to 400
0.1%
-
0.1%
0 to 400
0.1%
-
65
Data
Type
Hexadecimal
0 to E10
AUs16 Speed
-
AUs16 Speed
0 to FA0
AUs16
-
AUs16
0 to FA0
AUs16
-
AUs16
Remarks
Torque/
mag-
netic flux
Torque/
mag-
netic flux
Torque/
mag-
netic flux
Torque/
mag-
netic flux