APPENDIX C
DETAILED CELL INITIATED TEST ACTIONS
The following describes in more detail what goes on in a typical cell initiated sequence test. It includes internal func-
tions
to
the cellular telephone. This is only a brief summary. Refer to the AMPS specification for a more detailed
description and to find the definitions of various acronyms used.
R2008D/R2010D
Enter initial parameters through the initial parameters
screen of the tone memory mode.
SYSTEM ID
MOBILE ID
FOCC
FVC #1 TO
#4
FVC INCREMENT (AUTO TEST)
PRINTER (YES/NO)
Enter cell initiated sequence test _screen. The R2008D/
R2010D starts to send a continuous stream of system
parameter overhead messages.
Accept page response. Extract mobile number and serial
number and display on R2008D/R20IOD.
Send initial voice channel designation message.
Tune to FVC.
25
--
MOBILE
Power up mobile. Mobile performs DC power up task.
Mobile performs initialization task.
A. Scan control channels
B. Tune to R2008D/R20IOD FOCC.
C. Acquire word sync.
D. Receive overhead messages.
E. Update overhead information.
Perform paging channel selection task.
A. Scan paging channels.
B. Tune to R2008D/R2010D FOCC.
C. Acquire word sync.
D. Receive overhead message.
E. Perform overhead message processing task.
Enter idle task examine data for:
A. Paging match.
B. User request.
C. Order.
D. Overhead message.
Receive paging message. Perform page response task.
A. Scan access channels.
B. Tune
to
R2008D/R20IOD FOCC.
C. Acquire word sync.
D. Retrieve internal access parameters.
E. Wait random delay.
F. Seize RECC.
G. Perform service request subtask.
H. Enter await message subtask.