01
SUSPEND
02
RESTART
03
STATUS
04
RESET
APPENDIX F
MANUAL TEST COMMANDS
-Terminate the normal mode and enter the test mode. Perform initialization as specified b
the INIT command and await further test commands. The autonomous timer shall be rest
periodically unless a RESETOFF command received.
-Terminate the test mode, enter the normal mode and restart call processing tasks.
-Return the transceiver unit status
to
the R2008D/R2010D. Status definitions are:
PL:
Power level 0 (highest) - 7 (lowest)
CARR:
carrier (1-on)
TN:
Signaling tone (I-on)
TXM:
Transmit audio mute (!-muted)
RXM:
Receive audio mute (1-muted)
WS:
Word synchronization (1-ws acquired)
MODE:
!-control channel, 0-voice channel
Bl:
Current state of majority voted busy/idle
(0-busy, !-idle)
SAT:
SAT frequency is encoded as follows:
00- 5970HZ
OJ -6000HZ
· 10- 6030HZ
II- NO SAT LOCK
- Reset the autonomous timer
05
TURNAROUND -echo the byte following the command to the R2008D/R2010D
-requires
I
byte additional data
06
INIT
- lnrtialize the transceiver unit to the following state:
l - Carrier off
2- Attenuation - 0
DB
3 - Receive audio muted
4 - Transmit audio muted
5 - Signaling tone off
6 - Autonomous timer reset and its periodic resetting enabled
7- SAT-OFF
8 - DTMF and audio tones-off
07
CARRIER-ON
-Turn the carrier on. Transpond sat only if the SA TON command was previously receive<
08
CARRIER-OFF
-Turn the carrier off.
09
LOAD-SYNTH
-Set the synthesizer to the channel specified by the 4 digits following the command: e.g.
03~
sets synthesizer
to
channel #334.
10
SET-ATTN
-Set the RF power attenuation to the value specified in the data byte following the cor
man
d.
0-1 for lowest to high - attenuation
11
RXMUTE
-Mute the receive-audio signal.
12
RXUNMUTE
- Unmute the receive-audio signal.
13
TXMUTE
-Mute the transmit-audio signal.
14
TXUNMUTE
- Unmute the transmit-audio signaL
15
RESETOFF
(Discontinue periodic resetting of the autonomous timer (allow timer to time out).
16
STON
-Transmit a continuous signaling tone.