Field
Points/
Wiring
Common
Terminal
8
40-pin
connector
32
40-pin
connector
×2
8
Terminal
-
40-pin
32
connector
*3.....Value at TYP 200VAC.
*4.....Value at TYP 12VDC.
*5....."ERR." LED turns on when fuse is blown or external supply power is off.
*6.....0.08A is shown on the rating plate of the module.
*7.....0.15A is shown on the rating plate of the module.
Surge
Fuse
Suppression
Rating
1.6A
None
3.2A
None
3.2A
None
Zener diode
3.2A
5A
7A
None
None
1.6A
External
Power
Supply
Error
(TYP
display
DC24V)
Current
*5
LED
0.008A
None
0.011A
*5
LED
0.008A
None
0.012A
*5
LED
0.008A
None
0.014A
0.06A
0.015A
*5
LED
0.01A
None
-
*5
LED
0.15A *4
75
Internal
No. of
Current
Occupied
Consumption
Points
0.27A
16
0.079A*6
0.5A
32
0.141A*7
0.93A
64
0.17A
0.12A
0.12A
16
0.2A
0.11A
0.4A
32