ABB CV Series Instruction Leaflet
ABB CV Series Instruction Leaflet

ABB CV Series Instruction Leaflet

Voltage relay
Hide thumbs Also See for CV Series:

Advertisement

Quick Links

Effective: November 1999
Supersedes I.L. 41-201.4G, dated January 1997
( ) Denotes changes since previous issue
CONTENTS
This instruction leaflet applies to the follow-
ing types of relays:
• CV-1 Long Time Undervoltage Relay
• CV-2 Short Time Undervoltage Relay
• CV-4 Long Time Overvoltage Relay
• CV-5 Short Time Overvoltage Relay
• CV-6 Long Time Over or Undervoltage Relay
• CV-7 Short Time Over or Undervoltage Relay
• CV-8 Low Voltage Pickup Overvoltage Relay
!
CAUTION
Before putting relays into service, remove all
blocking which may have been inserted for the
purpose of securing the parts during ship-
ment, make sure that all moving parts operate
freely, inspect the contacts to see that they
are clean and close properly, and operate the
relay to check the settings and electrical con-
nections.
All possible contingencies which may arise during installation, operation or maintenance, and all details and
variations of this equipment do not purport to be covered by these instructions. If further information is
desired by purchaser regarding this particular installation, operation or maintenance of this equipment, the
local ABB Power T&D Company Inc. representative should be contacted.
ABB Automation Inc.
Substation Automation and Protection Division
Coral Springs, FL 33065
Type CV Voltage Relay
Class 1E Applications
1.0 APPLICATIONS
These relays have been specially designed and
tested to establish their suitability for Class 1E appli-
cations in accordance with the ABB Power T&D Com-
pany program for Class 1E Qualification Testing as
detailed in bulletin STR-1.
"Class 1E" is the safety classification of the electric
equipment and systems in nuclear power generating
stations that are essential to emergency shutdown of
the reactor, containment isolation, cooling of the reac-
tor, and heat removal from the containment and reac-
tor, or otherwise are essential in preventing significant
release of radioactive material to the environment.
The type CV relays are single-phase induction-disc
type relays operating either on under or over voltage
or both. These relays are applied as a voltage fault
detector operating in conjunction with other protective
relays. The relays are also used as timing devices for
various automatic operations.
2.0 CONSTRUCTION and OPERATION
The types CV-1, CV-2, CV-4, CV-5, CV-6 and CV-7
relays consist of a voltage unit, an auxiliary telephone
type relay and an indicating contactor switch (ICS).
The principal component parts of the relay and their
location are shown in Figure 1 (page 2).
The type CV-8 relay in addition to the above compo-
nents also has a capacitor which is series tuned with
the main coil of the electromagnet. This tuned circuit
Instruction Leaflet
41-201.4H

Advertisement

loading

Summary of Contents for ABB CV Series

  • Page 1 If further information is desired by purchaser regarding this particular installation, operation or maintenance of this equipment, the local ABB Power T&D Company Inc. representative should be contacted.
  • Page 2 41-201.4H CV Voltage Relay Class 1E Photo not available at this time Figure 1: Type CV Relay Without FT11 Case Figure 3: 67 Volt Type CV-8 Relay with Adjustable Pickup without FT-21 Case 2.1. VOLTAGE UNIT (CV) The overvoltage unit operates on the induction-disc principle.
  • Page 3 CV Voltage Relay Class 1E 41-201.4H two stationary contacts, completing the trip circuit. the moving contacts will leave the backstop of the For double circuit closing contacts, the moving con- time dial and move to close the front contacts. Nor- tacts bridge three stationary contacts.
  • Page 4 41-201.4H CV Voltage Relay Class 1E 3.2.2. Trip Circuit 4.0 SETTINGS The main contacts will close 30 amperes at 250 volts 4.1. CV UNIT dc and the seal-in contacts of the indicating contactor switch will carry this current long enough to trip a cir- The setting of the CV unit can be defined either by tap cuit breaker.
  • Page 5: Installation

    CV Voltage Relay Class 1E 41-201.4H For double trip relays, the upper stationary contact is mark on the time dial. For double trip relays, the fol- adjusted such that the contact rests solidly against the low on the stationary contacts should be approxi- backstop.
  • Page 6: Maintenance

    41-201.4H CV Voltage Relay Class 1E the time dial set to the indicated position, apply the 7.1.1. CV Unit voltages specified in Table 1 (e.g., for the CV-4, 140 Note: A spring shield covers the reset spring of percent of tap value voltage) and measure the oper- the CV unit.
  • Page 7 CV Voltage Relay Class 1E 41-201.4H Set the relay on the minimum tap setting and the time CV-6 and CV-7 Over or Undervoltage Relay — dial to position 6. Apply the indicated voltage of Table 1 and measure the operating time. Adjust the permanent magnet keeper until the operating time corresponds to the CV-4 and CV-5 Overvoltage, CV-6 and CV-7 Over value given in Table 1.
  • Page 8: Renewal Parts

    41-201.4H CV Voltage Relay Class 1E If the pickup is low, the front cover must be removed Pickup — The unit should pickup at 98% rating and and the leaf spring bent outward equally. not pickup at 85% of rating. If necessary, the cover leaf springs may be adjusted.
  • Page 9 CV Voltage Relay Class 1E 41-201.4H INDICATING CONTACTOR SWITCH INDUCTION UNIT CONTACT POSITION RELAY DE-ENERGIZED OVERVOLTAGE: OPEN UNDERVOLTAGE: CLOSED RESISTOR SHOWN CONNECTED FOR 125V OPERATION. MOVE FRONT LEAD TO ADJ. BAND FOR RED HANDLE 48V OPERATION. TEST SWITCH TERMINAL Sub 6 3517A43 Figure 4: Internal Schematic of Type CV Undervoltage or Overvoltage Relay in FT11 Case...
  • Page 10 41-201.4H CV Voltage Relay Class 1E RIGHT HAND CONTACT (FRONT VIEW) INDUCTION UNIT LEFT HAND CONTACT (FRONT VIEW) RESISTOR SHOWN CONNECTED FOR 125V OPERATION. MOVE FRONT LEAD TO ADJ. BAND FOR 48V OPERATION. RED HANDLE TEST SWITCH TERMINAL Sub 5 3519A53 Figure 5: Internal Schematic of Type CV Over or Undervoltage Relay, Without ICS Unit, in FT11 Case “T”...
  • Page 11 CV Voltage Relay Class 1E 41-201.4H RIGHT HAND INDUCTION CONTACT UNIT (FRONT VIEW) LEFT HAND CONTACT (FRONT VIEW) INDICATING CONTACTOR SWITCH RESISTOR SHOWN RED HANDLE CONNECTED FOR TEST SWITCH 125V OPERATION. MOVE FRONT LEAD TO ADJ. BAND FOR 48V OPERATION. TERMINAL Sub 5 3526A72...
  • Page 12 41-201.4H CV Voltage Relay Class 1E INDICATING CONTACTOR SWITCH INDUCTION UNIT CAPACITOR RESISTOR SHOWN CONNECTED FOR 125V OPERATION. MOVE FRONT LEAD TO ADJ. BAND FOR 48 V OPERATION. RED HANDLE TEST SWITCH TERMINAL Sub 5 3521A61 Figure 9: Internal Schematic of Type CV-8 Low Voltage Fixed Pickup in FT11 Case INDICATING CONTACTOR SWITCH...
  • Page 13 CV Voltage Relay Class 1E 41-201.4H Curve 619537 Figure 11: Typical Time Curves for Type CV-8 Low Pickup Overvoltage Relay...
  • Page 14 41-201.4H CV Voltage Relay Class 1E Curve 619541 Figure 12: Typical Time Curves Type CV-8 Over Voltage Relay with Resistor Set for Maximum Pickup Voltage...
  • Page 15 CV Voltage Relay Class 1E 41-201.4H...
  • Page 16 41-201.4H CV Voltage Relay Class 1E Curve 619536 Figure 14: Typical Time Curves for Type CV-1 Long Time Undervoltage Relay...
  • Page 17 CV Voltage Relay Class 1E 41-201.4H Curve 619535 Figure 15: Typical Time Curves for Type CV-2 Short Time Undervoltage Relay...
  • Page 18 41-201.4H CV Voltage Relay Class 1E Curve 1582C28 Figure 16: Typical Time Curves for Type CV-4 Long time Overvoltage Relay...
  • Page 19 CV Voltage Relay Class 1E 41-201.4H Curve 1582C31 Figure 17: Typical Time Curves for Type CV-5 Short Time Overvoltage Relay...
  • Page 20 41-201.4H CV Voltage Relay Class 1E...
  • Page 21 CV Voltage Relay Class 1E 41-201.4H...
  • Page 22 41-201.4H CV Voltage Relay Class 1E...
  • Page 23 CV Voltage Relay Class 1E 41-201.4H...
  • Page 24 41-201.4H CV Voltage Relay Class 1E Sub 2 1478B31 Sheet 1 of 2 Figure 22a: Typical External Schematic for Type CV Overvoltage or Undervoltage Relays Sub 2 1478B31 Sheet 2 of 2 Figure 22b: Typical External Schematic for Type CV Overvoltage or Undervoltage Relays...
  • Page 25 CV Voltage Relay Class 1E 41-201.4H...
  • Page 26 41-201.4H CV Voltage Relay Class 1E NOTES...
  • Page 27 CV Voltage Relay Class 1E 41-201.4H Sub 4 3519A65 Figure 24: Outline and Drilling Plan for the Type CV Relay in the FT-11 Case...
  • Page 28 41-201.4H CV Voltage Relay Class 1E Sub 4 3519A66 Figure 25: Outline and Drilling Plan for the Type CV-8 Relay in the FT21 Case ABB Automation Inc. 4300 Coral Ridge Drive Coral Springs Florida 33065 TEL: 954-752-6700 FAX: 954-345-5329 Printed in U.S.A.

This manual is also suitable for:

Cv-1Cv-2Cv-5Cv-6Cv-7Cv-8 ... Show all