Smart Power Supply Error Code 1 Flow Chart 1J "Bad Calibration Error (1) - GE T2100-ST1 Service Manual

Hide thumbs Also See for T2100-ST1:
Table of Contents

Advertisement

Smart Power Supply Error Code 1 Flow Chart 1J "Bad
Calibration Error (1)"
1J
Is the Red LED D13
flashing 1 time with a 4
second pause on the
Smart Power Supply
PCBLF0443-1?
Yes
Verify treadmill power switch is
in the off (O) position.
Perform Test Plug Procedure to
test elevation & treadmill
running belt, see Test Plug
Procedure for instructions.
Did treadmill cycle
according to Test
Plug Procedure?
Yes
Connect Stress System &
perform test.
Did treadmill
respond to Test
Procedure?
Yes
Return Treadmill
to service.
2097937-002 Rev G
11 March 2019
Is the Red LED D13
No
flashing on the Smart
Using the Full Vision Treadmill PS
New Cal software connect
communication thru RS232 or
USB.
Select
treadmill will start out slow and
increase speed to maximum.
Turn the treadmill power switch
OFF (O) for 10 seconds then turn
No
the power switch ON (-).
No
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Yes
Go To
Chart 1I
Power Supply
PCBLF0443-1?
Is the Red LED D13
flashing on the Smart
Power Supply
PCBLF0443-1?
No
Treadmill should
be operational.
Troubleshooting
No
Treadmill should
be operational.
the
Yes
Go To
Chart 1I
87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T2100-st2

Table of Contents