Fig. 7-22: F4.16 maximum pump pressure failure

7.10.4 Oil Change Warning / Error Function

Code
Name
Protection function control
F4.00
word
Warning
hours
F4.51
change
F4.52 Error hours of oil change
F4.53 Oil in operation time
F4.54 Reset oil in operation time 0...1
Tab. 7-22: Parameter list of oil change warning / error function
Once oil change monitoring function has been activated (F4.00 bit3), oil opera-
tion time will be counted and saved in [F4.53], if this time exceeds warning or
error level in [F4.51] or [F4.52], warning or error signal will be generated. Pa-
rameter F4.54 = 1 is used to reset the oil operation timer F4.53.
46/75
Setting range
0...15
Bit0: Pressure sensor failure (PSF)
Bit1: Actual pressure monitoring
Bit2: p/Q max. command limit
Bit3: Oil changing detection
of
oil
0...60,000 hours
0...60,000 hours
-
Default
Min.
0
-
36,000
1
40,000
1
-
-
0
-