7.10.3 Actual Pressure Monitoring
Code
F4.00 Protection function control word
F4.15 Maximum system pressure (warning) 0.0...[F4.16] bar
F4.16 Maximum pump pressure (error)
Tab. 7-21: Parameter list of pressure over limit detection
The detection of pressure feedback can be activated via bit1 of F4.00.
F4.15: When the feedback pressure goes beyond [F4.15], the warning (d0.88=1)
will be triggered for the pressure feedback surpassing the maximum system al-
lowed pressure.
F4.16: When the feedback pressure goes beyond [F4.16], the failure (d0.89=1)
will be triggered for the pressure feedback surpassing the pump limit pressure,
and then drive stops.
Fig. 7-21: F4.15 maximum system pressure warning
DOK-RCON03-FCP5020****-QU02-EN-P
Name
0...15
Bit0: Pressure sensor
failure (PSF)
Bit1: Actual pressure
monitoring
Bit2: p/Q max. com-
mand limit
Bit3: Oil changing detec-
tion
[F4.15]...4,000.0 bar
Block Diagram of Main Functions
Setting range
Default
500.0
1,000.0
Bosch Rexroth AG
Min.
Attri.
0
-
Run
0.1
Stop
0.1
Stop
45/75